Brick cutting, bad housekeeping too much debris in area. No GFCI on electrical cord, T-pole not secured....

176

Hazardous waste operation, truck driver with Tyvek suit and 1/2 face respirator....

667

There is no dust suppression system(water, local exhaust ventilation system), electrical connection should have GFCI. Brick mason should be using res...

672

Worker mixing mortar may need respiratory protection. Scaffolding not fully planked. Scaffold also needs additional cross bracing....

603

Monitoring workers during road milling operation. Controls (water, vacuum)should be used to reduce worker exposure levels....

608

Milling road surface to prepare for paving operation. Engineering controls (water spray, vacuum)should be used to reduce worker exposure levels. Whene...

607

Saw cutting concrete, no controls(water/vacuum). Use of engineering controls would reduce exposure levels. Saw being operated at an awkward angle....

605

Saw cutting concrete with no controls (water/vacuum). Use of engineering controls would reduce worker exposure level....

611

Rock crushing operation, operator would reduce exposure level by closing cab door. Rock crusher operator may need to increase water spray to reduce du...

612

Rock crushing operation. Water spray or a local exhaust system can reduce exposure levels....