Table B4. Pressure losses and air flows through DustControl 2700 vacuum cleaner: 09/13/2007 Round 2

Before (B) or after (A) adding 5 pounds

Total weight added to vacuum cleaner (lb)

Venturi meter δP (inches of water)

Static Pressure Measurements with manometer (inches of water)1

Absolute pressures measured with pressure transducers.(psi)

Time to start loading

Time to stop loading

Filter pressure loss inches of water, corrected for calibration curve of the pressure transducers

Air flow from venturi meter (cfm)

Upstream "before cyclone"

Downstream "after cyclone"

δP

Upstream of final filter (55481)

Downstream of filter at inlet to vacuum cleaner motor (53478)

B

5

7.3

-4

-8

4

13.824

13.147

12:53 pm

12:56pm

19.23

71.12

A

7.2

-3.8

-5.8

2

13.899

13.13

 

 

21.77

70.63

B

5

7.7

-4.4

-6.9

2.5

13.874

13.197

1:00pm

1:02pm

19.22

73.02

A

7.7

-4.2

-6.2

2

13.891

13.13

 

 

21.55

73.02

B

5

8.8

-4.4

-6.2

1.8

13.874

13.18

1:15pm

1:17pm

19.69

77.99

A

7.7

-4.1

-6.3

2.2

13.891

13.08

 

 

22.93

73.02

B

5

8.9

-3.9

-6.2

2.3

13.874

13.13

1:26pm

1:27pm

21.08

78.43

A

8

-4.1

-6.3

2.2

13.883

13.088

 

 

22.49

74.41

B

5

7.7

-4.3

-10

5.7

13.84

13.088

2:00pm

2:02pm

21.30

73.02

A

7.4

-4.1

-6.1

2

13.857

13.071

 

 

22.24

71.60

B

5.2

8.9

-5.1

-7.1

2

13.849

13.172

2:08pm

2:10pm

19.23

78.43

A

8.4

-4.4

-7

2.6

13.857

13.088

 

 

21.77

76.22

B

5

8.2

-4.5

-6.6

2.1

13.849

13.205

2:16pm

2:18pm

18.31

75.32

A

8

-4.5

-6.4

1.9

13.866

13.055

 

 

22.93

74.41

Final

 

8.7

-4.6

-6.7

2.1

13.832

13.238

2:22pm

 

16.93

77.55

1 Static pressure is the difference in pressure from atmospheric pressure. Negative static pressure indicates that pressure is less than atmospheric pressure.

This paper appears in the eLCOSH website with the permission of the author and/or copyright holder and may not be reproduced without their consent. eLCOSH is an information clearinghouse. eLCOSH and its sponsors are not responsible for the accuracy of information provided on this web site, nor for its use or misuse.

CPWR – The Center for Construction Research and Training is a 501-c-3 organization affiliated with the Building and Construction Trades Council, AFL-CIO, and serves as the research arm of the BCTD. CPWR provides safety and health research and information for the construction trades and industry. For more information, visit www.cpwr.com.